THREE PHASE INDUCTION MOTOR CONVERSION TO THREE PHASE INDUCTION GENERATOR USING CAPACITORS

Authors

  • Zuhair Sameen Shuker Department of Electrical Engineering, Baquba Technical Institute, Middle Technical University, Baghdad, Iraq Author

Keywords:

Three-phase IM, Three-phase IG, Power load, Capacitors

Abstract

This paper presents an experimental investigation of the conversion of the three-phase induction motors (IM) to run as three-phase induction generators (IG) by using capacitors proportional to the load power and the generator power. The potential of these capacitors must not be less than 450 V and connected in parallel with three-phase output. The generator must be run on full load to balance the inductive loads which connect to a generator with the capacitive loads. The experimental results indicate that the three phases IM with high power reaches 90 KW can be led as three phases IG with power (112.5 KVA).

Downloads

Published

2015-09-01

How to Cite

THREE PHASE INDUCTION MOTOR CONVERSION TO THREE PHASE INDUCTION GENERATOR USING CAPACITORS . (2015). Journal of Engineering and Sustainable Development, 19(5), 163-173. https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/821