Experimental Investigation on the Effect of the Use of Steel Wire Meshes on Shear Transfer Strength of Reinforced Concrete Push-Off Specimens

المؤلفون

  • Nibras N. Al-Chalabi Civil Engineering Department, Al-Mustansiriyah University, Baghdad, Iraq مؤلف

الكلمات المفتاحية:

.

الملخص

Using push-off specimens with shear plan length of 200mm and depth of 100mm, the influence of the addition of relatively widely spaced layers of steel wire meshes on shear transfer strength of reinforced concrete was experimentally investigated in this study. Eleven push-off specimens were fabricated and were divided into three groups depending on the number of layers of wire meshes crossing the shear plan. The other studied parameters were the shear parameter of the conventional stirrups (ρfy) and the angle of the plan of the steel wire mesh layers to shear plan of the push-off specimens.Using push-off specimens with shear plan length of 200mm and depth of 100mm, the influence of the addition of relatively widely spaced layers of steel wire meshes on shear transfer strength of reinforced concrete was experimentally investigated in this study. Eleven push-off specimens were fabricated and were divided into three groups depending on the number of layers of wire meshes crossing the shear plan. The other studied parameters were the shear parameter of the conventional stirrups and the angle of the plan of the steel wire mesh layers to shear plan of the push-off specimens.The test results showed that the use of relatively widely spaced (about 40mm) steel wire meshes has only trivial effect on ...

   

التنزيلات

Key Dates

منشور

2011-03-01

كيفية الاقتباس

Experimental Investigation on the Effect of the Use of Steel Wire Meshes on Shear Transfer Strength of Reinforced Concrete Push-Off Specimens. (2011). مجلة الهندسة والتنمية المستدامة, 15(1), 205-215. https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1361