Experimental Investigation on the Effect of the Use of Steel Wire Meshes on Shear Transfer Strength of Reinforced Concrete Push-Off Specimens

Authors

  • Nibras N. Al-Chalabi Civil Engineering Department, Al-Mustansiriyah University, Baghdad, Iraq Author

Keywords:

.

Abstract

Using push-off specimens with shear plan length of 200mm and depth of 100mm, the influence of the addition of relatively widely spaced layers of steel wire meshes on shear transfer strength of reinforced concrete was experimentally investigated in this study. Eleven push-off specimens were fabricated and were divided into three groups depending on the number of layers of wire meshes crossing the shear plan. The other studied parameters were the shear parameter of the conventional stirrups (ρfy) and the angle of the plan of the steel wire mesh layers to shear plan of the push-off specimens.Using push-off specimens with shear plan length of 200mm and depth of 100mm, the influence of the addition of relatively widely spaced layers of steel wire meshes on shear transfer strength of reinforced concrete was experimentally investigated in this study. Eleven push-off specimens were fabricated and were divided into three groups depending on the number of layers of wire meshes crossing the shear plan. The other studied parameters were the shear parameter of the conventional stirrups and the angle of the plan of the steel wire mesh layers to shear plan of the push-off specimens.The test results showed that the use of relatively widely spaced (about 40mm) steel wire meshes has only trivial effect on ...

   

Downloads

Key Dates

Published

2011-03-01

How to Cite

Experimental Investigation on the Effect of the Use of Steel Wire Meshes on Shear Transfer Strength of Reinforced Concrete Push-Off Specimens. (2011). Journal of Engineering and Sustainable Development, 15(1), 205-215. https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1361