Numerical Analysis of Refrigerant Flow in Different Types Of Capillary Tubes Used R1270

المؤلفون

  • Haider Ali Hussen Mechanical Engineering Department, Mustansiriyah University, Baghdad, Iraq مؤلف

الكلمات المفتاحية:

Coiled، Serpentine، Capillary tube، Adiabatic، Refrigerants، Flow

الملخص

The capillary tube is a common expansion device used in small-sized refrigeration and air-conditioning systems. The main focus lies on the analysis of the refrigerant flow behavior along the capillary tube with different shapes (straight-coiled-serpentine) as well as using alternative (R1270) with different geometrical parameters by using a commercial code FORTRAN power station for the simulation. Capillary geometrical parameters will include diameter, coiled diameter, and curve diameter. Results showed that when capillary tube internal diameter increases from 1.4 mm to 1.8 mm. Straight tube length increases from (1.2978m) to (4.8738m) with ratio (73.37%) , Coiled tube length increases from (0.589m) to (1.958m) with ratio (69.91%) at coiled diameter (dd=10mm) ,and The serpentine tube length increases from (0.859m) to (2.671m) with ratio (67.84%) at curve radius ( )or curve diameter (dr=10mm).. The ideal capillary tube type is coiled. Because length decrease with a comparison between straight and serpentine.

التنزيلات

Key Dates

منشور

2013-12-01

كيفية الاقتباس

Numerical Analysis of Refrigerant Flow in Different Types Of Capillary Tubes Used R1270. (2013). مجلة الهندسة والتنمية المستدامة, 17(6), 10-21. https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1020