Strength of Concrete Using Different Types of Additives

Authors

  • Ali Hussain Ali Technical Engineering College, Mosul, Iraq Author

Keywords:

Silica fume, Crushed glass, Crushed nucleate, compressive strength, tensile strength, flexural strength

Abstract

In this investigation, conventional concrete mixes (as a reference mixes) and concretemixes produced with (5, 10, and 20)% of cement replacement by silica fume, crushed glass and crushed nucleate additives respectively, these mixes were used in preparing (144) concrete specimens. Laboratory test results in dictated that:

a)There was a significant increase (17.6 to 88.5 and 8.8 to 25.8) % in the compressive strength of concretes produced with silica fume and crushed glass additives respectively, while a significant reduction (29.6 to 62.6)% in the compressive strength was recorded using concrete mixes with crushed nucleate.
b)there lation ships between the 7-day(fc,7)and:the28day(fc,28)compressive strength areas follows
- [fc,28 = 1.701 fc,7] for (reference mix);
- [fc,28 = (1.590 to 1.931) fc,7] for silica fume mixes;

Downloads

Key Dates

Published

2011-12-01

How to Cite

Strength of Concrete Using Different Types of Additives. (2011). Journal of Engineering and Sustainable Development, 15(4), 30-48. https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1306

Similar Articles

1-10 of 388